R32 MONOBLOC DC INVERTER HEAT PUMP

R32 is a fully packaged unit, where the indoor and outdoor units are combined as one module.
This unit does not require refrigerant piping work since the Monobloc's outdoor unit is connected exclusively to water piping.
Description
Description
Heat Pumps Monoblock R290

Product Description

Functional Positioning and Target Users

The R32 Monobloc DC Inverter Heat Pump is designed primarily for residential heating and cooling applications where simplified installation is preferred. As a fully integrated monobloc unit, it avoids indoor refrigerant piping, connecting only to water lines, suited for replacing traditional boilers or retrofitting existing heating systems. This solution targets distributors and OEM buyers focused on energy-efficient and compact heat pump options.

Technical Features and Source-Backed Specifications

This heat pump uses the refrigerant R32, which offers a significant reduction in global warming potential compared to conventional refrigerants. It operates reliably in outdoor temperatures down to -25°C and can supply water temperatures up to 75°C, accommodating existing radiator systems. The unit features a full DC inverter compressor and fan for energy-saving operation, a 5-inch touchscreen controller, smartphone remote access, and smart grid compatibility, as outlined in the product technical data.

Application Fit and Practical Value

Suitable for new constructions and retrofit projects, the R32 Monobloc DC Inverter Heat Pump integrates easily with existing hot water systems and boilers for hybrid setups. Its monobloc design simplifies logistics and installation, reducing on-site labor. This heat pump can be sourced for projects requiring eco-friendly refrigerants and high energy efficiency, with specifications matching diverse residential climates and operational demands.


Product Advantages

Procurement-Relevant Design

The monobloc form factor reduces installation complexity by eliminating indoor refrigerant lines, simplifying inventory and on-site work. Using an R32 refrigerant aligns with regulatory trends toward lower global warming potential substances, supporting compliance and environmental requirements. The unit’s packaged design aids in standardizing procurement with fewer components to manage.

Operational Fit and Supply Considerations

With full DC inverter technology and smart grid compatibility, this heat pump suits energy-conscious projects where operational flexibility is required. Its documented capability to maintain performance in cold climates increases its market applicability. For OEM or wholesale buyers, the product availability in several capacities provides options to meet a range of project sizes. Packaging and delivery details are designed to facilitate protected transport and straightforward integration into existing distribution channels.


Use Scenarios

Residential Heating System Replacement

In residential retrofit projects, this heat pump serves as a direct replacement for conventional boilers without changing the home’s radiator infrastructure. It connects solely to water piping, facilitating quicker installation and minimizing disruption. Its compatibility with cold ambient temperatures and water delivery temperatures up to 75°C makes it suitable for colder regions, meeting demand from distributors supplying renovation solutions.

OEM and Distribution for New Build Projects

For new construction developments, the compact monobloc design eases installation and reduces space requirements, advantageous for builders and OEM buyers. Its energy rating and refrigerant choice align with increasing energy codes and environmental standards. Distributors can offer this model as part of integrated heating and cooling system packages, benefiting from compatibility with smart grid technologies and remote control features relevant to modern building management systems.

Modern Technology to Replace Conventional Boilers
Full DC inverter heat pump for house heating and colling, a government
recommended solution to replace traditional boilers
R32 Refrigerant
Due to accelerated global warming and the destruction of the ozone layer, various international conventions and meetings are held to enhance restrictions to the use of refrigerant or enforce the use of eco-conscious refrigerant R32 is internationally acclaimed for being eco-friendly. This low volume refrigerant is as efficient as any conventional refrigerant but boasts a 68% reduced global warming potential. Therefore Greenpower develops R32 monobloc DC Inverter heat pump, contributing to the reduction of carbon emission and help achieve the global goal of carbon neutrality.
Energy efficiency, high class A+++
Greenpower R32 monobloc DC Inverter heat pump is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does Greenpower heat pumps use R32 green gas and inverter technology, but also is rated with A+++ energy label. With top energy rating A+++, the unit is energy efficient and can greatly reduce energy bills for users.
Wide operation range
In heating mode, Greenpower R32 monobloc DC Inverter heat pump can work at lowest temperature to -25°C, and maximum output temperature 75°C, which can be the best choise for old radiators need high water temperature.
Solution overview
Monobloc
Line-up R32 Monobloc
1Ø :  6 / 9 / 12 / 18kW
3Ø : 
12 / 18 / 24kW
Application
Energy Label
Operation Range (heating) Outdoor Air -25 ~ 45°C
Leaving Water 10 ~ 75°C
Customer Needs Designer & Installer 1. Don't want refrigerant piping work  2. Using existing facilities for conventional boiler  3. Saving installation and commissioning time  4. No indoor unit
End-User 1. Low operation cost   2. Control integration between boiler and heat pump  3. Reliable operation and long lifetime   4. Remote control by smartphone  5. Easy and intuitive controls  6. Quiet operation
- Don't want to install refrigerant piping indoors
Approach 1. High energy efficiency  2. Wi-Fi control solution 3. Interlocking operation with 3rd party boiler  4. High corrosion resistance heat exchanger  5. Low noise mode operation with schedule setting
- All in one concept (no refrigerant piping work)
Benefit 1. Multiple solution (heating, cooling and DHW supply)  2. Hybrid operation with existing facilities  3. Energy saving by utilizing renewable  4. Quick & easy installation and commissioning  5. Economic support by incentive program energy and high efficient equipment
- Simple replacement of existing boiler while maintaining the existing heating system
- Saving mechanical room space
Unique Features
User Convenience | Green power R32 monobloc DC Inverter heat pump is equipped with various user convenience functions, which allow for enhanced comfort and control. The textbased user-friendly interface on the remote control allows for optimized user intuition and the unit's wide connectivity also provide user control convenience.
Excellent Performance & Efficiency | Green power R32 monobloc DC Inverter heat pump provides world-class energy efficiency by adopting revolutionary technology. The products have achieved a high heating performance even in extremely cold weather conditions and can bring customers peace of mind through product reliability.
Easy Installation & Maintenance | Green power R32 monobloc DC Inverter heat pump offers installation and design flexibility to professional installers.The Heating Configurator also allows professionals to save time during commissioning. During maintenance, the clip type connection allows fast and easy disassembly of the components.
SG Ready and Smart Grid
Green power R32 monobloc DC Inverter heat pump is operated automatically according to the status signals received from power supply companies.This function can correspond to each country’s specific tariff for heat pump application on smart grids.



Controller with Intuitive Interface
Green power R32 monobloc DC Inverter heat pump is equipped with privately designed, 5 inch colorful touch screen, which is very friendly-use for clients, and has the very simple interface to show the power consumption daily, monthly and yearly.



Bring You A Silent time
Green power R32 monobloc DC Inverter heat pump adopts super quiet full DC inverter compressor and full DC inverter fan motor system which could bring you a very silent time. Meanwhile, it could provide a special silent mode which could be more silent and no bother to your neighbors.





Specification

FAQ

Can you customize heat pump designs for specific project needs?
We offer ODM, OEM, and co-design services to tailor heat pump products based on your exact specifications. Whether you need modifications on our standard models or fully new designs, we support customization to fit various applications including r290 monobloc heat pump configurations.

What installation requirements does the R32 Monobloc DC Inverter Heat Pump have?
Our heat pump’s monobloc design means no indoor refrigerant piping is needed; only water piping connections are required indoors. This simplifies installation and reduces onsite labor compared to traditional split systems or r290 split heat pump setups.

How do you ensure product quality and reliability for international clients?
We maintain stable quality by partnering directly with branded suppliers such as GMCC and Swep, alongside in-house R&D and control system expertise. This strict sourcing and development process guarantees consistent performance and durability across all heat pumps including our r290 heat pump manufacturer offerings.

What maintenance support do you provide for your heat pumps?
Our fully integrated monobloc units are designed for easy maintenance with fewer components indoors, reducing service complexity. We also provide technical guidance and spare parts support to help maintain efficient operation throughout the lifespan of your r290 dc inverter heat pump or any model in our portfolio.
Send your message to us
please select your country
  • Afghanistan
  • Aland Islands
  • Albania
  • Algeria
  • American Samoa
  • Andorra
  • Angola
  • Anguilla
  • Antigua and Barbuda
  • Argentina
  • Armenia
  • Aruba
  • Australia
  • Austria
  • Azerbaijan
  • Bahamas
  • Bahrain
  • Bangladesh
  • Barbados
  • Belarus
  • Belgium
  • Belize
  • Benin
  • Bermuda
  • Bhutan
  • Bolivia
  • Bosnia and Herzegovina
  • Botswana
  • Bouvet Island
  • Brazil
  • British Indian Ocean Territory
  • British Virgin Islands
  • Brunei Darussalam
  • Bulgaria
  • Burkina Faso
  • Burundi
  • Cambodia
  • Cameroon
  • Canada
  • Cape Verde
  • Caribbean Netherlands
  • Cayman Islands
  • Central African Republic
  • Chad
  • Chile
  • Christmas Island
  • Cocos Islands
  • Colombia
  • Comoros
  • Congo
  • Cook Islands
  • Costa Rica
  • Cote D'ivoire
  • Cuba
  • Curaçao
  • Cyprus
  • Czech Republic
  • Democratic People's Republic of Korea
  • Democratic Republic of the Congo
  • Denmark
  • Djibouti
  • Dominica
  • East Timor
  • Ecuador
  • Egypt
  • El Salvador
  • Equatorial Guinea
  • Eritrea
  • Estonia
  • Ethiopia
  • Falkland Islands
  • Faroe Islands
  • Fiji
  • Finland
  • France
  • French Guiana
  • French Polynesia
  • French Southern Territories
  • Gabon
  • Gambia
  • Georgia
  • Germany
  • Ghana
  • Gibraltar
  • Greece
  • Greenland
  • Grenada
  • Guadeloupe
  • Guam
  • Guatemala
  • Guernsey
  • Guinea
  • Guinea-Bissau
  • Guyana
  • Haiti
  • Heard Island and Mcdonald Islands
  • Honduras
  • Hong Kong, China
  • Hungary
  • Iceland
  • India
  • Indonesia
  • Iran
  • Iraq
  • Ireland
  • Isle of Man
  • Israel
  • Italy
  • Jamaica
  • Jordan
  • Kazakhstan
  • Kenya
  • Kiribati
  • Korea
  • Kosovo
  • Kuwait
  • Kyrgyzstan
  • Laos
  • Latvia
  • Lebanon
  • Lesotho
  • Liberia
  • Liechtenstein
  • Lithuania
  • Luxembourg
  • Macau, China
  • Madagascar
  • Malawi
  • Malaysia
  • Maldives
  • Mali
  • Malta
  • Marshall Islands
  • Martinique
  • Mauritania
  • Mauritius
  • Mayotte
  • Mexico
  • Micronesia
  • Moldova
  • Monaco
  • Mongolia
  • Montenegro
  • Montserrat
  • Morocco
  • Mozambique
  • Myanmar
  • N.Macedonia
  • Namibia
  • Nauru
  • Nepal
  • Netherlands
  • Netherlands Antilles
  • New Caledonia
  • New Zealand
  • Nicaragua
  • Niger
  • Nigeria
  • Niue
  • Norfolk Island
  • Northern Mariana Islands
  • Norway
  • Oman
  • Pakistan
  • Palau
  • Palestine
  • Panama
  • Papua New Guinea
  • Paraguay
  • Peru
  • Philippines
  • Pitcairn Islands
  • Poland
  • Portugal
  • Puerto Rico
  • Qatar
  • Reunion
  • Romania
  • Russia
  • Rwanda
  • Saint Barthélemy
  • Saint Helena
  • Saint Kitts and Nevis
  • Saint Lucia
  • Saint Martin
  • Saint Pierre and Miquelon
  • Saint Vincent and the Grenadines
  • San Marino
  • Sao Tome and Principe
  • Saudi Arabia
  • Senegal
  • Serbia
  • Seychelles
  • Sierra Leone
  • Singapore
  • Sint Maarten
  • Slovakia
  • Slovenia
  • Solomon Islands
  • Somalia
  • South Africa
  • South Georgia and The South Sandwich Islands
  • Spain
  • Sri Lanka
  • State of Libya
  • Sudan
  • Suriname
  • Svalbard and Jan Mayen
  • Swaziland
  • Sweden
  • Switzerland
  • Syrian Arab Republic
  • TaiWan, China
  • Tajikistan
  • Tanzania
  • Thailand
  • The Republic of Croatia
  • Togo
  • Tokelau
  • Tonga
  • Trinidad and Tobago
  • Tunisia
  • Turkey
  • Turkmenistan
  • Turks and Caicos Islands
  • Tuvalu
  • Uganda
  • Ukraine
  • United Arab Emirates
  • United Kingdom
  • United States
  • United States Minor Outlying Islands
  • Uruguay
  • US Virgin Islands
  • Uzbekistan
  • Vanuatu
  • Vatican City State
  • Venezuela
  • Vietnam
  • Wallis and Futuna Islands
  • Western Sahara
  • Western Samoa
  • Yemen
  • Zambia
  • Zimbabwe
ver_code