R32 MONOBLOC DC INVERTER HEAT PUMP

R32 is a fully packaged unit, where the indoor and outdoor units are combined as one module.
This unit does not require refrigerant piping work since the Monobloc's outdoor unit is connected exclusively to water piping.
Description
Description
Heat Pumps Monoblock R290 

Product Description

Functional Positioning and Target Users

The unit serves as a self-contained r290 monobloc heat pump solution integrating indoor and outdoor components into a single assembly. It targets projects requiring straightforward installation and servicing by eliminating indoor refrigerant piping. Procurement of this type of r290 heat pump typically aligns with retrofit or new residential heating and cooling system upgrades emphasizing reduced installation complexity.

Technical Features and Source-Backed Specifications

This heat pump employs r290 refrigerant recognized for its low global warming potential and operational efficiency. The system supports a wide operating range adaptable to outdoor temperatures from -25°C up to 45°C, and hot water delivery up to 75°C. Its integrated inverter compressor and touchscreen control facilitate energy management and user interface functions. Manufactured models cover various capacities, enabling selection matched to specific project heat load requirements.

Application Fit and Real-World Value

The product is suited for residential and commercial applications where integration with existing water-based heating infrastructure is necessary, or where high water temperatures are needed for radiators. Its monobloc design reduces installation time and technical challenges, which can improve project timelines. Buyers can consider this r290 heat pump for operations requiring low noise emission and remote control capability, supporting practicality in urban or noise-sensitive environments.


Product Advantages

Procurement-Relevant Design

The monobloc configuration simplifies logistics and onsite setup by removing the need for refrigerant piping. This structural design can reduce installation labor costs and potential leak points. Use of r290 refrigerant aligns with regulatory pressures favoring low-GWP solutions, pertinent for compliance in certain markets. OEM and ODM options can support customization requests related to controller interfaces or capacity scaling.

Operational Fit and Supply Considerations

The product offers a range of output capacities, facilitating adaptation to varying project scales. Stability in component sourcing is supported by collaboration with established suppliers in compressor and control system hardware. The inclusion of a touchscreen controller with Wi-Fi does not introduce additional complexity for experienced servicing personnel. Packaging and delivery considerations focus on a fully integrated unit, suitable for streamlined distribution to regional installers or distributors.


Use Scenarios

Residential Retrofit and Replacement Projects

In residential retrofit scenarios, the r290 monobloc heat pump replaces conventional boilers or older heat pumps, connecting directly to the existing water piping system without requiring refrigerant line installation. This reduces disruption and installation time for mid-size projects. Its operational temperature range suits climates with cold winters, supporting continued heating performance without auxiliary systems. Procurement agents valuing ease of installation and retrofit compatibility may prioritize this solution.

OEM and Distribution Channel Applications

The product’s modular monobloc design and varied capacity range support its use by OEMs and heat pump distributors targeting segmented market needs. Its use of r290 refrigerant addresses demand for environmentally regulated product lines. Distributors can rely on consistent component quality and advanced control features, facilitating resale and integration into packaged systems. The unit’s compliance with typical energy rating requirements aids in meeting local policy and customer expectations.


Modern Technology to Replace Conventional Boilers
Full DC inverter heat pump for house heating and colling, a government
recommended solution to replace traditional boilers

R32 Refrigerant
Due to accelerated global warming and the destruction of the ozone layer, various international conventions and meetings are held to enhance restrictions to the use of refrigerant or enforce the use of eco-conscious refrigerant R32 is internationally acclaimed for being eco-friendly. This low volume refrigerant is as efficient as any conventional refrigerant but boasts a 68% reduced global warming potential. Therefore Greenpower develops R32 monobloc DC Inverter heat pump, contributing to the reduction of carbon emission and help achieve the global goal of carbon neutrality.
Energy efficiency, high class A+++
Greenpower R32 monobloc DC Inverter heat pump is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does Greenpower heat pumps use R32 green gas and inverter technology, but also is rated with A+++ energy label. With top energy rating A+++, the unit is energy efficient and can greatly reduce energy bills for users.
Wide operation range
In heating mode, Greenpower R32 monobloc DC Inverter heat pump can work at lowest temperature to -25°C, and maximum output temperature 75°C, which can be the best choise for old radiators need high water temperature.
Solution overview
Monobloc
Line-up R32 Monobloc
1Ø :  6 / 9 / 12 / 18kW
3Ø : 
12 / 18 / 24kW
Application
Energy Label
Operation Range (heating) Outdoor Air -25 ~ 45°C
Leaving Water 10 ~ 75°C
Customer Needs Designer & Installer 1. Don't want refrigerant piping work  2. Using existing facilities for conventional boiler  3. Saving installation and commissioning time  4. No indoor unit
End-User 1. Low operation cost   2. Control integration between boiler and heat pump  3. Reliable operation and long lifetime   4. Remote control by smartphone  5. Easy and intuitive controls  6. Quiet operation
- Don't want to install refrigerant piping indoors
Approach 1. High energy efficiency  2. Wi-Fi control solution 3. Interlocking operation with 3rd party boiler  4. High corrosion resistance heat exchanger  5. Low noise mode operation with schedule setting
- All in one concept (no refrigerant piping work)
Benefit 1. Multiple solution (heating, cooling and DHW supply)  2. Hybrid operation with existing facilities  3. Energy saving by utilizing renewable  4. Quick & easy installation and commissioning  5. Economic support by incentive program energy and high efficient equipment
- Simple replacement of existing boiler while maintaining the existing heating system
- Saving mechanical room space
Unique Features
User Convenience | Green power R32 monobloc DC Inverter heat pump is equipped with various user convenience functions, which allow for enhanced comfort and control. The textbased user-friendly interface on the remote control allows for optimized user intuition and the unit's wide connectivity also provide user control convenience.
Excellent Performance & Efficiency | Green power R32 monobloc DC Inverter heat pump provides world-class energy efficiency by adopting revolutionary technology. The products have achieved a high heating performance even in extremely cold weather conditions and can bring customers peace of mind through product reliability.
Easy Installation & Maintenance | Green power R32 monobloc DC Inverter heat pump offers installation and design flexibility to professional installers.The Heating Configurator also allows professionals to save time during commissioning. During maintenance, the clip type connection allows fast and easy disassembly of the components.
SG Ready and Smart Grid
Green power R32 monobloc DC Inverter heat pump is operated automatically according to the status signals received from power supply companies.This function can correspond to each country’s specific tariff for heat pump application on smart grids.



Controller with Intuitive Interface
Green power R32 monobloc DC Inverter heat pump is equipped with privately designed, 5 inch colorful touch screen, which is very friendly-use for clients, and has the very simple interface to show the power consumption daily, monthly and yearly.



Bring You A Silent time
Green power R32 monobloc DC Inverter heat pump adopts super quiet full DC inverter compressor and full DC inverter fan motor system which could bring you a very silent time. Meanwhile, it could provide a special silent mode which could be more silent and no bother to your neighbors.





Specification


FAQ 

What installation requirements does the R32 Monobloc DC Inverter Heat Pump have?
Our R32 Monobloc design requires only water piping connections, eliminating refrigerant piping indoors. This simplifies installation, reduces labor costs, and improves safety. We provide easy commissioning tools and clip-type connections, ensuring rapid setup and maintenance for your project.

Can you customize heat pumps for specific project needs?
Yes, we offer ODM, OEM, and co-design services. Whether you need standard r290 heat pump models or require modifications for easy mass production, we adapt to your design specifications. For strategic partners, we collaborate on fully custom solutions to meet unique requirements.

How do you ensure quiet operation in your heat pumps?
Our r290 monobloc heat pump and other models feature full DC inverter compressors and fan motors with a special silent mode. This design significantly reduces noise levels, making our units suitable for residential installations where low acoustic disturbance is critical.

What logistics and supply chain measures support your heat pump delivery?
We maintain direct cooperation with branded component suppliers like Highly and GMCC and control system developers. This stable supply chain allows us to offer competitive prices and reliable availability of r290 dc inverter heat pump components, ensuring timely delivery for your orders.
Send your message to us
please select your country
  • Afghanistan
  • Aland Islands
  • Albania
  • Algeria
  • American Samoa
  • Andorra
  • Angola
  • Anguilla
  • Antigua and Barbuda
  • Argentina
  • Armenia
  • Aruba
  • Australia
  • Austria
  • Azerbaijan
  • Bahamas
  • Bahrain
  • Bangladesh
  • Barbados
  • Belarus
  • Belgium
  • Belize
  • Benin
  • Bermuda
  • Bhutan
  • Bolivia
  • Bosnia and Herzegovina
  • Botswana
  • Bouvet Island
  • Brazil
  • British Indian Ocean Territory
  • British Virgin Islands
  • Brunei Darussalam
  • Bulgaria
  • Burkina Faso
  • Burundi
  • Cambodia
  • Cameroon
  • Canada
  • Cape Verde
  • Caribbean Netherlands
  • Cayman Islands
  • Central African Republic
  • Chad
  • Chile
  • Christmas Island
  • Cocos Islands
  • Colombia
  • Comoros
  • Congo
  • Cook Islands
  • Costa Rica
  • Cote D'ivoire
  • Cuba
  • Curaçao
  • Cyprus
  • Czech Republic
  • Democratic People's Republic of Korea
  • Democratic Republic of the Congo
  • Denmark
  • Djibouti
  • Dominica
  • East Timor
  • Ecuador
  • Egypt
  • El Salvador
  • Equatorial Guinea
  • Eritrea
  • Estonia
  • Ethiopia
  • Falkland Islands
  • Faroe Islands
  • Fiji
  • Finland
  • France
  • French Guiana
  • French Polynesia
  • French Southern Territories
  • Gabon
  • Gambia
  • Georgia
  • Germany
  • Ghana
  • Gibraltar
  • Greece
  • Greenland
  • Grenada
  • Guadeloupe
  • Guam
  • Guatemala
  • Guernsey
  • Guinea
  • Guinea-Bissau
  • Guyana
  • Haiti
  • Heard Island and Mcdonald Islands
  • Honduras
  • Hong Kong, China
  • Hungary
  • Iceland
  • India
  • Indonesia
  • Iran
  • Iraq
  • Ireland
  • Isle of Man
  • Israel
  • Italy
  • Jamaica
  • Jordan
  • Kazakhstan
  • Kenya
  • Kiribati
  • Korea
  • Kosovo
  • Kuwait
  • Kyrgyzstan
  • Laos
  • Latvia
  • Lebanon
  • Lesotho
  • Liberia
  • Liechtenstein
  • Lithuania
  • Luxembourg
  • Macau, China
  • Madagascar
  • Malawi
  • Malaysia
  • Maldives
  • Mali
  • Malta
  • Marshall Islands
  • Martinique
  • Mauritania
  • Mauritius
  • Mayotte
  • Mexico
  • Micronesia
  • Moldova
  • Monaco
  • Mongolia
  • Montenegro
  • Montserrat
  • Morocco
  • Mozambique
  • Myanmar
  • N.Macedonia
  • Namibia
  • Nauru
  • Nepal
  • Netherlands
  • Netherlands Antilles
  • New Caledonia
  • New Zealand
  • Nicaragua
  • Niger
  • Nigeria
  • Niue
  • Norfolk Island
  • Northern Mariana Islands
  • Norway
  • Oman
  • Pakistan
  • Palau
  • Palestine
  • Panama
  • Papua New Guinea
  • Paraguay
  • Peru
  • Philippines
  • Pitcairn Islands
  • Poland
  • Portugal
  • Puerto Rico
  • Qatar
  • Reunion
  • Romania
  • Russia
  • Rwanda
  • Saint Barthélemy
  • Saint Helena
  • Saint Kitts and Nevis
  • Saint Lucia
  • Saint Martin
  • Saint Pierre and Miquelon
  • Saint Vincent and the Grenadines
  • San Marino
  • Sao Tome and Principe
  • Saudi Arabia
  • Senegal
  • Serbia
  • Seychelles
  • Sierra Leone
  • Singapore
  • Sint Maarten
  • Slovakia
  • Slovenia
  • Solomon Islands
  • Somalia
  • South Africa
  • South Georgia and The South Sandwich Islands
  • Spain
  • Sri Lanka
  • State of Libya
  • Sudan
  • Suriname
  • Svalbard and Jan Mayen
  • Swaziland
  • Sweden
  • Switzerland
  • Syrian Arab Republic
  • TaiWan, China
  • Tajikistan
  • Tanzania
  • Thailand
  • The Republic of Croatia
  • Togo
  • Tokelau
  • Tonga
  • Trinidad and Tobago
  • Tunisia
  • Turkey
  • Turkmenistan
  • Turks and Caicos Islands
  • Tuvalu
  • Uganda
  • Ukraine
  • United Arab Emirates
  • United Kingdom
  • United States
  • United States Minor Outlying Islands
  • Uruguay
  • US Virgin Islands
  • Uzbekistan
  • Vanuatu
  • Vatican City State
  • Venezuela
  • Vietnam
  • Wallis and Futuna Islands
  • Western Sahara
  • Western Samoa
  • Yemen
  • Zambia
  • Zimbabwe
ver_code