R32 MONOBLOC DC INVERTER HEAT PUMP

R32 is a fully packaged unit, where the indoor and outdoor units are combined as one module.
This unit does not require refrigerant piping work since the Monobloc's outdoor unit is connected exclusively to water piping.
Description
Description
Heat Pumps Monoblock R290

Product Description

Functional Positioning and Target Users

The r290 heat pump is developed for applications requiring energy-efficient water heating and climate control, addressing residential and light commercial needs. Its design supports streamlined installation, making it suitable for users seeking alternatives to conventional boilers or fossil fuel systems. Both standalone and hybrid setups are applicable with this product type, assisting in sustainable heating transitions.

Technical Features and Source-Backed Specifications

This r290 dc inverter heat pump includes fully integrated modules that minimize indoor refrigerant piping, connecting primarily to water circuits. It operates within a wide temperature range, capable of maintaining hot water output at temperatures appropriate for radiator systems or domestic use. Inverter-driven compressors help optimize energy consumption while allowing dynamic adjustment to varying thermal loads, aligning with eco-friendly refrigerant usage standards.

Application Fit and Real-World Value

Ideal for projects requiring straightforward installation and compatibility with existing heating infrastructure, the r290 hot water heat pump provides a feasible solution for energy-conscious building upgrades. It suits climates with cold seasons where maintaining stable hot water supply is necessary. Its design supports OEM/ODM customization and adapts well within hybrid heating systems, enhancing practical deployment across diverse procurement scenarios.


 Product Advantages

Procurement-Relevant Design

The r290 monobloc heat pump’s integration of compressor and heat exchange components into single packaged units reduces onsite installation complexity and can decrease labor costs. This modular approach can improve supply chain efficiency for distributors or wholesale operations targeting fast deployment. Its compliance with refrigerant safety and environmental standards also aligns with current regulatory requirements for commercial projects.

Operational Fit for Business Use

Suppliers and procurement managers will value the product’s adaptability to various power supply configurations and its inverter technology that adjusts output to demand, which may reduce energy consumption and operating expenses. The option for OEM/ODM customization provides flexibility for clients seeking tailored heat pump solutions. Packaging and quality control protocols from the manufacturer support regular volume supply and project timelines.


Use Scenarios

Residential and Small Commercial Heating Projects

In residential refurbishment or new build settings, the r290 air to water heat pump can replace traditional boilers, providing water heating via existing radiators or underfloor systems. Its monobloc configuration saves indoor installation time and mitigates refrigerant handling concerns indoors, making it suitable for project managers focusing on compliance and streamlined installation. It can operate reliably in colder climates, delivering consistent hot water to meet occupant needs.

Wholesale Distribution and OEM/ODM Partnerships

Distributors sourcing from an r290 heat pump manufacturer can integrate these units into broader renewable heating portfolios, meeting demand from multiple end users or local installers. Its modular design supports customization requests, aligning with OEM/ODM client requirements for differentiated product offerings. The heat pump’s compatibility with hybrid setups enhances its application range, appealing to projects aiming to upgrade heating systems with energy-saving technologies.

Modern Technology to Replace Conventional Boilers
Full DC inverter heat pump for house heating and colling, a government
recommended solution to replace traditional boilers
R32 Refrigerant
Due to accelerated global warming and the destruction of the ozone layer, various international conventions and meetings are held to enhance restrictions to the use of refrigerant or enforce the use of eco-conscious refrigerant R32 is internationally acclaimed for being eco-friendly. This low volume refrigerant is as efficient as any conventional refrigerant but boasts a 68% reduced global warming potential. Therefore Greenpower develops R32 monobloc DC Inverter heat pump, contributing to the reduction of carbon emission and help achieve the global goal of carbon neutrality.
Energy efficiency, high class A+++
Greenpower R32 monobloc DC Inverter heat pump is specially developed with the most cutting-edge heat pump technology and modern design to meet stringent requirements for efficiency, stability and quietness. Not only does Greenpower heat pumps use R32 green gas and inverter technology, but also is rated with A+++ energy label. With top energy rating A+++, the unit is energy efficient and can greatly reduce energy bills for users.
Wide operation range
In heating mode, Greenpower R32 monobloc DC Inverter heat pump can work at lowest temperature to -25°C, and maximum output temperature 75°C, which can be the best choise for old radiators need high water temperature.
Solution overview
Monobloc
Line-up R32 Monobloc
1Ø :  6 / 9 / 12 / 18kW
3Ø : 
12 / 18 / 24kW
Application
Energy Label
Operation Range (heating) Outdoor Air -25 ~ 45°C
Leaving Water 10 ~ 75°C
Customer Needs Designer & Installer 1. Don't want refrigerant piping work  2. Using existing facilities for conventional boiler  3. Saving installation and commissioning time  4. No indoor unit
End-User 1. Low operation cost   2. Control integration between boiler and heat pump  3. Reliable operation and long lifetime   4. Remote control by smartphone  5. Easy and intuitive controls  6. Quiet operation
- Don't want to install refrigerant piping indoors
Approach 1. High energy efficiency  2. Wi-Fi control solution 3. Interlocking operation with 3rd party boiler  4. High corrosion resistance heat exchanger  5. Low noise mode operation with schedule setting
- All in one concept (no refrigerant piping work)
Benefit 1. Multiple solution (heating, cooling and DHW supply)  2. Hybrid operation with existing facilities  3. Energy saving by utilizing renewable  4. Quick & easy installation and commissioning  5. Economic support by incentive program energy and high efficient equipment
- Simple replacement of existing boiler while maintaining the existing heating system
- Saving mechanical room space
Unique Features
User Convenience | Green power R32 monobloc DC Inverter heat pump is equipped with various user convenience functions, which allow for enhanced comfort and control. The textbased user-friendly interface on the remote control allows for optimized user intuition and the unit's wide connectivity also provide user control convenience.
Excellent Performance & Efficiency | Green power R32 monobloc DC Inverter heat pump provides world-class energy efficiency by adopting revolutionary technology. The products have achieved a high heating performance even in extremely cold weather conditions and can bring customers peace of mind through product reliability.
Easy Installation & Maintenance | Green power R32 monobloc DC Inverter heat pump offers installation and design flexibility to professional installers.The Heating Configurator also allows professionals to save time during commissioning. During maintenance, the clip type connection allows fast and easy disassembly of the components.
SG Ready and Smart Grid
Green power R32 monobloc DC Inverter heat pump is operated automatically according to the status signals received from power supply companies.This function can correspond to each country’s specific tariff for heat pump application on smart grids.



Controller with Intuitive Interface
Green power R32 monobloc DC Inverter heat pump is equipped with privately designed, 5 inch colorful touch screen, which is very friendly-use for clients, and has the very simple interface to show the power consumption daily, monthly and yearly.



Bring You A Silent time
Green power R32 monobloc DC Inverter heat pump adopts super quiet full DC inverter compressor and full DC inverter fan motor system which could bring you a very silent time. Meanwhile, it could provide a special silent mode which could be more silent and no bother to your neighbors.




Specification


FAQ

What installation requirements does the R32 Monobloc DC Inverter Heat Pump have?
Our R32 Monobloc DC Inverter Heat Pump features a fully integrated monobloc design requiring only water piping indoors, eliminating refrigerant piping inside the building. This approach simplifies installation, reduces potential leak risks, and accelerates setup time for industrial-scale or residential projects.

Can you customize the heat pump model for specific project needs?
Yes, we offer ODM, OEM, and co-design services to tailor our heat pumps according to your specifications. Whether you require adaptations for performance, size, or controls, our engineering team collaborates closely to develop solutions suitable for mass production or unique applications.

How does the heat pump handle operation in freezing outdoor environments?
Our product operates efficiently down to an outdoor air temperature of -25°C, maintaining reliable heating performance. This makes it suitable for cold climates. The full DC inverter compressor technology ensures system stability while providing hot water up to 75°C even in subzero conditions.

Are spare parts and maintenance supported for your r290 heat pump products?
We provide comprehensive after-sales support, including spare parts and maintenance advice for our r290 heat pump and related units. Our long-term partnerships with branded suppliers ensure availability of key components, helping you maintain efficient operation with minimal downtime. Contact us for service details.
Send your message to us
please select your country
  • Afghanistan
  • Aland Islands
  • Albania
  • Algeria
  • American Samoa
  • Andorra
  • Angola
  • Anguilla
  • Antigua and Barbuda
  • Argentina
  • Armenia
  • Aruba
  • Australia
  • Austria
  • Azerbaijan
  • Bahamas
  • Bahrain
  • Bangladesh
  • Barbados
  • Belarus
  • Belgium
  • Belize
  • Benin
  • Bermuda
  • Bhutan
  • Bolivia
  • Bosnia and Herzegovina
  • Botswana
  • Bouvet Island
  • Brazil
  • British Indian Ocean Territory
  • British Virgin Islands
  • Brunei Darussalam
  • Bulgaria
  • Burkina Faso
  • Burundi
  • Cambodia
  • Cameroon
  • Canada
  • Cape Verde
  • Caribbean Netherlands
  • Cayman Islands
  • Central African Republic
  • Chad
  • Chile
  • Christmas Island
  • Cocos Islands
  • Colombia
  • Comoros
  • Congo
  • Cook Islands
  • Costa Rica
  • Cote D'ivoire
  • Cuba
  • Curaçao
  • Cyprus
  • Czech Republic
  • Democratic People's Republic of Korea
  • Democratic Republic of the Congo
  • Denmark
  • Djibouti
  • Dominica
  • East Timor
  • Ecuador
  • Egypt
  • El Salvador
  • Equatorial Guinea
  • Eritrea
  • Estonia
  • Ethiopia
  • Falkland Islands
  • Faroe Islands
  • Fiji
  • Finland
  • France
  • French Guiana
  • French Polynesia
  • French Southern Territories
  • Gabon
  • Gambia
  • Georgia
  • Germany
  • Ghana
  • Gibraltar
  • Greece
  • Greenland
  • Grenada
  • Guadeloupe
  • Guam
  • Guatemala
  • Guernsey
  • Guinea
  • Guinea-Bissau
  • Guyana
  • Haiti
  • Heard Island and Mcdonald Islands
  • Honduras
  • Hong Kong, China
  • Hungary
  • Iceland
  • India
  • Indonesia
  • Iran
  • Iraq
  • Ireland
  • Isle of Man
  • Israel
  • Italy
  • Jamaica
  • Jordan
  • Kazakhstan
  • Kenya
  • Kiribati
  • Korea
  • Kosovo
  • Kuwait
  • Kyrgyzstan
  • Laos
  • Latvia
  • Lebanon
  • Lesotho
  • Liberia
  • Liechtenstein
  • Lithuania
  • Luxembourg
  • Macau, China
  • Madagascar
  • Malawi
  • Malaysia
  • Maldives
  • Mali
  • Malta
  • Marshall Islands
  • Martinique
  • Mauritania
  • Mauritius
  • Mayotte
  • Mexico
  • Micronesia
  • Moldova
  • Monaco
  • Mongolia
  • Montenegro
  • Montserrat
  • Morocco
  • Mozambique
  • Myanmar
  • N.Macedonia
  • Namibia
  • Nauru
  • Nepal
  • Netherlands
  • Netherlands Antilles
  • New Caledonia
  • New Zealand
  • Nicaragua
  • Niger
  • Nigeria
  • Niue
  • Norfolk Island
  • Northern Mariana Islands
  • Norway
  • Oman
  • Pakistan
  • Palau
  • Palestine
  • Panama
  • Papua New Guinea
  • Paraguay
  • Peru
  • Philippines
  • Pitcairn Islands
  • Poland
  • Portugal
  • Puerto Rico
  • Qatar
  • Reunion
  • Romania
  • Russia
  • Rwanda
  • Saint Barthélemy
  • Saint Helena
  • Saint Kitts and Nevis
  • Saint Lucia
  • Saint Martin
  • Saint Pierre and Miquelon
  • Saint Vincent and the Grenadines
  • San Marino
  • Sao Tome and Principe
  • Saudi Arabia
  • Senegal
  • Serbia
  • Seychelles
  • Sierra Leone
  • Singapore
  • Sint Maarten
  • Slovakia
  • Slovenia
  • Solomon Islands
  • Somalia
  • South Africa
  • South Georgia and The South Sandwich Islands
  • Spain
  • Sri Lanka
  • State of Libya
  • Sudan
  • Suriname
  • Svalbard and Jan Mayen
  • Swaziland
  • Sweden
  • Switzerland
  • Syrian Arab Republic
  • TaiWan, China
  • Tajikistan
  • Tanzania
  • Thailand
  • The Republic of Croatia
  • Togo
  • Tokelau
  • Tonga
  • Trinidad and Tobago
  • Tunisia
  • Turkey
  • Turkmenistan
  • Turks and Caicos Islands
  • Tuvalu
  • Uganda
  • Ukraine
  • United Arab Emirates
  • United Kingdom
  • United States
  • United States Minor Outlying Islands
  • Uruguay
  • US Virgin Islands
  • Uzbekistan
  • Vanuatu
  • Vatican City State
  • Venezuela
  • Vietnam
  • Wallis and Futuna Islands
  • Western Sahara
  • Western Samoa
  • Yemen
  • Zambia
  • Zimbabwe
ver_code